Phriction Projects Wikis Bioimaging And Optics Platform Image Processing [OBSOLETE] Whole Slide Image (WSI) Registration With ImageJ/Fiji, Elastix and QuPath History Version 56 vs 61
Version 56 vs 61
Version 56 vs 61
Content Changes
Content Changes
WARNING: [A NEW VERSION OF THIS WORKFLOW IS AVAILABLE FOR QUPATH V0.3.0](https://c4science.ch/w/warpy/ ). The documentation below is there for legacy reasons, and works with QuPath v0.2.3. Note that the transformations generated by this workflow are compatible with QuPath v0.3.0. Only the analysis scripts in QuPath have to be changed. So you can transfer your QuPath v0.2.3 project to QuPath v0.3 without too much effort (hopefully)
NOTE: The new workflow for QuPath 0.3.0 is accessible here: https://c4science.ch/w/warpy/
This page documents a way to register whole slide images in Fiji and analyze their result in QuPath. This workflow allows to register slides with transformations which are **more complex than affine transform**, by using the ImgLib2 library, elastix, and BigWarp. Reasonably, if the sample is not too deformed, registration at the cellular level can be achieved on the whole slide.
= Videos tutorials
These videos have been created on the 9th of April 2021, they could become outdated faster than the written documentation below!
[Playlist](https://www.youtube.com/watch?v=E4k2CGbvQTM&list=PL2PJpdamvntgXgF0YF_FKeYzn34RITfar)
* [Installation](https://www.youtube.com/watch?v=E4k2CGbvQTM)
* [Registration](https://www.youtube.com/watch?v=HAdktWdngWU)
* [Analysis](https://www.youtube.com/watch?v=uDglj4Lvxak)
= Installation
== ImageJ / Fiji
=== BigDataViewer-Playground update site ===
Enable the [BigDataViewer-Playground](https://imagej.github.io/plugins/bdv/playground) update site, then restart Fiji. This update site is accessible in the list of Fiji's update site under the name `BigDataViewer-Playground`.
=== Elastix - To enable automated registrations capabilities ===
** Download the [latest release of elastix for your OS](https://github.com/SuperElastix/elastix/releases/tag/5.0.1). This documentation has been tested for elastix 5.0.1.
** Unzip it somewhere convenient ( `C` drive on windows, in `Applications` for Mac )
**Windows **
For windows users, you also need to install [Visual C++ redistributable](https://support.microsoft.com/en-us/topic/the-latest-supported-visual-c-downloads-2647da03-1eea-4433-9aff-95f26a218cc0), you'll most probably need `vc_redist.x64.exe`
**Mac**
Fiji will be calling the elastix executables, which are recognized as ‘unknown developers’ by Mac OS. Thus you need to make security exceptions for both elastix and transformix (https://support.apple.com/en-hk/guide/mac-help/mh40616/mac) to avoid clicking indefinitely on the OS warning messages.
**Linux (not tested)**
Nothing particular should be required for linux system.
=== Indicate `elastix` and `transformix` executable location in Fiji ===
*** Execute {nav Plugins › BIOP › Set and Check Wrappers} then indicate the proper location of executable files {F18020664,width = 500}
*** This should show up in the ImageJ console : `[INFO] Transformix -> set :-) Elastix -> set :-)`
Once elastix is installed, you can run [the following script](https://gist.githubusercontent.com/NicoKiaru/b91f9f3f0069b765a49b5d4629a8b1c7/raw/571954a443d1e1f0597022f6c19f042aefbc0f5a/TestRegister.groovy) in Fiji to test elastix functionality. Save the file with a `.groovy` extension, open it Fiji, and run it.
== QuPath
Install the [QuPath version 0.2.3](https://github.com/qupath/qupath/releases/tag/v0.2.3)
Install the QuPath biop extensions and its dependencies:
* download jar files (https://drive.google.com/file/d/1NzNu4U0c_9zwcp-gV2x3HD5lg5MJib6z/view?usp=sharing)
* Extract the files and put its content them into a folder named `extensions` within another folder (for instance {nav C>QuPath Common Data>extensions}
* Specify the location of the `QuPath Common Data` folder into QuPath {nav Edit>Preferences} and restart QuPath
{F18165963,width = 500}
When QuPath is restarted, a BIOP menu should appear on top of the QuPath window:
{F18022329,width = 500}
= WSI registration - step by step procedure
To follow the WSI registration procedure, a demo dataset, consisting of a fluorescent image which can be registered to a RGB H-DAB image, can be [downloaded here](https://zenodo.org/record/4680455#.YHQk3D-xW00).
== Create your QuPath project
[Create first a QuPath project](https://qupath.readthedocs.io/en/latest/docs/tutorials/projects.html) containing all the slides that you want to register.
{F18022361, width = 400}
WARNING: Only the Bio-Formats image builder is supported on the Fiji side. Make sure to select `Bio-Formats builder` when importing your slides, and leave unchecked `Auto generate pyramids`.
If your image can't be loaded in QuPath using the `Bio-Formats builder`, you can convert your slides in `ome.tiff` format. Several options are available, for instance by using [bfconvert with Kheops](https://c4science.ch/w/bioimaging_and_optics_platform_biop/image-processing/imagej_tools/ijp-kheops/), or [bioformatsf2raw](https://c4science.ch/w/bioimaging_and_optics_platform_biop/image-processing/qupath/ome-tiff-conversion/) for a fast conversion.
WARNING: All files need to be properly calibrated (microns, millimeters, etc, but not pixels!). Check on the image tab of QuPath that you have a proper physical unit specified, and not pixels!
{F18022412,width = 400}
Save your project, and you are done for now on the QuPath side.
NOTE: You can let QuPath open while performing the registration on Fiji.
== Registration in Fiji
=== Open your QuPath project
In Fiji, open your QuPath project using {nav Plugins › BigDataViewer › Playground › BDVDataset › Open [QuPath Project] }. You can also directly type `QuPath` in Fiji's search bar to avoid struggling in Fiji's menu hierarchy.
* Select your qupath project file (usually named `project.qpproj`).
* Let the default options but make sure to select **MILLIMETER** in the `physical units of the dataset` field
{F18022564,width = 400}
NOTE: the `physical units of the dataset` field actually indicates how you want to import your dataset. Bio-Formats takes care of converting the unit of the acquisition into millimeters. This can be achieved only if the image is correctly calibrated initially: bio-formats knows how to converts from microns to millimeters, or from angström to millimeters, but it can't know how to transform from pixels to millimeters.
NOTE: this WSI registration workflow hides many registration parameters by making use of the proper calibration in physical units, and by assuming it targets a cellular resolution level (do not expect registration precision at 50 nm resolution, unless you manually correct it with BigWarp).
After you have opened your Project, a window called `BDV Sources` should pop-up. If you double click on the `Sources` node, you should be able to browse the hierarchy and see the "sources" contained in your QuPath project. Note that the fluorescent channels have been splitted into separated sources. In the demo file, you get a window like this:
{F18022649,width =250}
* `DAB.tif-ch0` is the RGB DAB image
* `TileScan_001_Merging001-ch0` is the DAPI fluorescent channel
* `TileScan_001_Merging001-ch1` is the other fluorescent channel, which staining is similar to DAB
For the demo dataset registration, you can choose the DAB image as the fixed image, and the DAPI channel as the moving image.
=== Coarse manual pre-registration
The automated registration works if the images are approximately pre-aligned in the world coordinate space. This section explains how to check and correct the initial location of sources if they are not approximately aligned.
NOTE: If you do not want to use automated registrations, you can skip this part and just go to the next Wizard section and select `manual BigWarp registration` in the wizard.
To check if this is the case, you will need to display the two slides you want to align in a BigDataViewer window. To do this:
* select the slides that you want to align in the tree view. For this, you may find convenient to expand {nav SpimData 0> QuPathEntryEntity}, and select, using `ctrl+click`, the two entities you want to align:
{F18022728,width = 250}
* With these selected, right-click and select `BDV - Show Sources (new BDV Window)`
{F18022737,width = 400}
* Select the options as below:
{F18022742,width = 500}
* For the demo dataset, you will get something like this:
{F18022750,width = 600}
You can hover with your mouse on the right part of the panel to see a blue arrow that you can click:
{F18269212, width = 600}
With this right panel you can activate or deactivate sources. You notice that the fluorescent image, while of the correct size, is shifted in XY to the DAB image. This needs to be corrected before going further. If your images are already approximately aligned, you can skip the part below and go to the wizard section.
NOTE: Navigating within BigDataViewer requires a bit of experience. In 2D, the minimal commands to know are written below:
- **hold and drag right-click**: Pan;
- **mouse wheel (or up / down key)**: zoom in and out;
- **`shift` modifier key**: zoom in or out faster,
- **`ctrl` modifier key**: more precise zoom.
- You'll soon notice that holding **`left-click`** rotates the view. To go back to the default rotation, click **`shift+Z`**
You need to modify the location of the fluorescent image in order to approximately put it at its proper location. Here's a way to manually do it:
* Select the fluorescent sources in the tree view (all fluorescent channels should be selected, either by selecting an upstream node, like in the picture below, or by selected both fluorescent channels)
{F18024665, width=250}
* Right-click and select `Manual Sources Transformation`, choose mutate or append (it doesn't matter for this use case):
{F18024672, width=400}
{F18024676, width=250}
* Center the sources by panning the bdv window, the selected sources in the tree view will stay still (you stay in the referential of the moving sources)
{F18024689, size=full}
{F18024694, size=full}
* Click `Apply and finish` (or `Cancel` and then repeat the operation if something went wrong)
You now have an approximately registered slide to one another.
{F18024730, size=full}
Congrats, you can go to the next step.
=== Wizard : automated registration
You can start the wizard by clicking {nav Plugins › BigDataViewer › Playground › Sources › Register › Wizard Align Slides For QuPath} or just type `Wizard` in the search bar and select the correct command when it shows up.
First, select the DAB source as the fixed source, and the DAPI channel as the moving source that will be used for the registration as indicated in the image below:
{F18024767, width=700}
Another wizard window shows up:
{F18024780, width=700}
Successive steps of registration happens consecutively, all are optional. If the sample is not too streched or damaged from one scan to the other, a fully automated registration (skipping step 2 - Manual spline registration (BigWarp) ) will give cellular resoution results, but it's a good idea to check the results with BigWarp anyway, even if the landmarks are not modified because the registration is already tipptopp.
NOTE: If you check `show results of automated registrations`, ImageJ1 images will be created and show the different images which are effectively sent to elastix for automated registration. It's a good way to check the intermediate steps and see what could have gone wrong. However, the processing will be slower because each step happen sequentially instead of in a parallel fashion.
In the rest of this section, we assume all registration steps have been checked. If not, some of the details below will not be asked.
==== Step 1 - Set Bdv window to cover both moving and fixed slide
{F18024883, width=250}
During this step, you just need to have a bdv window open and selected and all the area of the slides you want to register should be visible, as in the image below:
{F18024899, width=700}
Click `OK` to go to the second step
==== Step 2 - Define a rectangular ROI for the registration
TOFIX: It's not clearly visible, but there's actually a message overlaid in BDV: `Select a rectangular region for the region you want to register`. TODO : Github Issue
{F18024912, width=700}
So just draw a rectangle spanning the region you want to register, by drawing a rectangle on bdv, holding mouse left button:
{F18024943, width=700}
==== Step 3 - Define position of landmarks that should be automatically registered
TOFIX : It's not clearly visible, but there's actually a message overlaid in BDV: `Select the position of the landmarks`
{F18024960, width=700}
Using the mouse left button, position points that will be used to locally correct the warping of the moving slide. You can concentrate the landmark on the regions you are more interested in. Here's an example of landmarks positionning:
{F18024977, width=700}
The number of necessary landmarks is not obvious to know in advance. You need to place them however where common structures are easily identifiable in both the moving and fixed image, a bit like how you would place focus points during your acquisition.
NOTE: To go to the next step, just press `Escape`. This part of the UI needs improvement (TODO : github issue)
NOTE: The automated registration should take about 20 seconds. If it takes longer, check that there's no error message in the ImageJ console.
==== Step 4 - Manually correct landmarks
If you have selected `Manual spline registration (BigWarp)`, you will now be able to manually investigate and correct landmarks that have been automatically registered, and also add new landmarks to the slides, if you want to adjust more precisely a particular region. The interface used is directly the one of [BigWarp](https://imagej.github.io/plugins/bigwarp), so please check the documentation of BigWarp itself in order to edit landmarks.
Here's a convenient way to perform this step:
* First, ignore the moving image window and increase the size of the BigWarp fixed image.
{F18025076, width=700}
* press `F1` for help window
* press `F` to toggle ON and OFF the registered moving image (F stands for fused)
* zoom (mouse wheel) and pan (drag left? or right? TOFIX mouse button) to investigate the registration quality
* press `ctrl+D` to move to the next landmark
To correct a landmark position:
* press `space` to enter the landmark mode
* carefully select and drag a landmark to modify its position. Live visualization of the transformed image helps you positioning it correctly
* press `space` to exit landmark mode
* navigate and repeat for each landmark that needs correction
To add another landmark:
* in landmark mode, press `ctrl + left click` to pin a new landmark on both the moving and fixed image at the current mouse location. It can then be dragged.
Once you are satisfied with the registration, click `OK`
{F18025114, width=300}
==== Step 5 - Succesful registration message
If all went smoothly, you should get this message:
{F18025129, width=300}
This means that the result of the registration has been stored as a file into your QuPath project. It can then be used from within QuPath to transfer annotations and or detections from one slide to another one, as explained in the next section.
NOTE: the transformation is stored as a json file in the data entry folder of the TOFIX fixed?moving? image. It is named by convention `transform_{i}_{j}.json` where `i` and `j` are the index of the fixed and the the moving image in the QuPath project.
== Analysis in QuPath
From within QuPath, annotations and or detections can be transfered within registered images, one way or another. Indeed, provided transformations are regular enough, they are invertible.
To transfer annotations or detections from one image to another:
* using the procedure of your choice (cell detection plugin, stardist, manual annotation, etc.), create annotations or detections on the image of your choice (for instance the moving image).
* move to the other registered image (for instance the fixed image).
* you can then execute the following script {nav Automate > User scripts... > New Script... }:
```
lang=javascript, name=transform_objects.groovy
import ch.epfl.biop.qupath.transform.TransformHelper
// Get the current image data
def imageData = getCurrentImageData()
// Transfer all matching annotations and detections, keeps hierarchy,
// transfer measurements (first true parameter)
// allow to use inverse transforms (second true parameter)
TransformHelper.transferMatchingAnnotationsToImage(imageData, true, true)
// Computes all intensities measurements in the new image
def server = getCurrentServer()
TransformHelper.addIntensityMeasurements(getAnnotationObjects(), server, 1, true)
//If the image is RGB, this line can be added to import the correct measurements (DAB, etc.) :
//
//server = new qupath.lib.images.servers.TransformedServerBuilder(getCurrentServer())
// .deconvolveStains(getCurrentImageData().getColorDeconvolutionStains(), 1, 2)
// .build()
//cf https://forum.image.sc/t/transferring-segmentation-predictions-from-custom-masks-to-qupath/43408/15
```
The above scripts consists of two parts:
* `TransformHelper.transferMatchingAnnotationsToImage` looks through all images of the QuPath project if there are transformations files will allow to transfer annotations and detections from one image to the current (target) one, and then performs the transfer.
* transfered annotations/detections does not contain the standard measurements provided by QuPath (fluorescent intensity / DAB value, etc.) In order to add the measurements on the target image, the function `TransformHelper.addIntensityMeasurements(getAnnotationObjects(), server, 1, true)` can be called
== Troubleshooting
Something's wrong in this documentation ? Please post your issue or question in the [image.sc forum](image.sc forum).
== References (papers)
* [Fiji](http://www.nature.com/nmeth/journal/v9/n7/full/nmeth.2019.html)
* [QuPath](https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5715110/)
* [BigWarp](http://ieeexplore.ieee.org/document/7493463/)
* [Elastix (1)](http://dx.doi.org/10.1109/TMI.2009.2035616) [Elastix (2)](http://dx.doi.org/10.3389/fninf.2013.00050)
* [BigDataViewer](http://www.nature.com/nmeth/journal/v12/n6/full/nmeth.3392.html)
== References (github)
The code to perform this workflow is splitted in several parts:
[Qupath extensions](https://github.com/BIOP/qupath-biop-extensions) and several repositories for the fiji side. On the fiji side, the main components are [Bigdataviewer-playground](https://github.com/bigdataviewer/bigdataviewer-playground) for the management of multiple sources and [Bigdataviewer-biop-tools](https://github.com/BIOP/bigdataviewer-biop-tools), for various functionalities, for instance the QuPath bridge.
WARNING: [A NEW VERSION OF THIS WORKFLOW IS AVAILABLE FOR QUPATH V0.3.0](https://c4science.ch/w/warpy/ ). The documentation below is there for legacy reasons, and works with QuPath v0.2.3. Note that the transformations generated by this workflow are compatible with QuPath v0.3.0. Only the analysis scripts in QuPath have to be changed. So you can transfer your QuPath v0.2.3 project to QuPath v0.3 without too much effort (hopefully)
NOTE: The new workflow for QuPath 0.3.0 is accessible here: https://c4science.ch/w/warpy/
This page documents a way to register whole slide images in Fiji and analyze their result in QuPath. This workflow allows to register slides with transformations which are **more complex than affine transform**, by using the ImgLib2 library, elastix, and BigWarp. Reasonably, if the sample is not too deformed, registration at the cellular level can be achieved on the whole slide.
= Videos tutorials
These videos have been created on the 9th of April 2021, they could become outdated faster than the written documentation below!
[Playlist](https://www.youtube.com/watch?v=E4k2CGbvQTM&list=PL2PJpdamvntgXgF0YF_FKeYzn34RITfar)
* [Installation](https://www.youtube.com/watch?v=E4k2CGbvQTM)
* [Registration](https://www.youtube.com/watch?v=HAdktWdngWU)
* [Analysis](https://www.youtube.com/watch?v=uDglj4Lvxak)
= Installation
== ImageJ / Fiji
=== BigDataViewer-Playground update site ===
Enable the [BigDataViewer-Playground](https://imagej.github.io/plugins/bdv/playground) update site, then restart Fiji. This update site is accessible in the list of Fiji's update site under the name `BigDataViewer-Playground`.
=== Elastix - To enable automated registrations capabilities ===
** Download the [latest release of elastix for your OS](https://github.com/SuperElastix/elastix/releases/tag/5.0.1). This documentation has been tested for elastix 5.0.1.
** Unzip it somewhere convenient ( `C` drive on windows, in `Applications` for Mac )
**Windows **
For windows users, you also need to install [Visual C++ redistributable](https://support.microsoft.com/en-us/topic/the-latest-supported-visual-c-downloads-2647da03-1eea-4433-9aff-95f26a218cc0), you'll most probably need `vc_redist.x64.exe`
**Mac**
Fiji will be calling the elastix executables, which are recognized as ‘unknown developers’ by Mac OS. Thus you need to make security exceptions for both elastix and transformix (https://support.apple.com/en-hk/guide/mac-help/mh40616/mac) to avoid clicking indefinitely on the OS warning messages.
**Linux (not tested)**
Nothing particular should be required for linux system.
=== Indicate `elastix` and `transformix` executable location in Fiji ===
*** Execute {nav Plugins › BIOP › Set and Check Wrappers} then indicate the proper location of executable files {F18020664,width = 500}
*** This should show up in the ImageJ console : `[INFO] Transformix -> set :-) Elastix -> set :-)`
Once elastix is installed, you can run [the following script](https://gist.githubusercontent.com/NicoKiaru/b91f9f3f0069b765a49b5d4629a8b1c7/raw/571954a443d1e1f0597022f6c19f042aefbc0f5a/TestRegister.groovy) in Fiji to test elastix functionality. Save the file with a `.groovy` extension, open it Fiji, and run it.
== QuPath
Install the [QuPath version 0.2.3](https://github.com/qupath/qupath/releases/tag/v0.2.3)
Install the QuPath biop extensions and its dependencies:
* download jar files (https://drive.google.com/file/d/1NzNu4U0c_9zwcp-gV2x3HD5lg5MJib6z/view?usp=sharing)
* Extract the files and put its content them into a folder named `extensions` within another folder (for instance {nav C>QuPath Common Data>extensions}
* Specify the location of the `QuPath Common Data` folder into QuPath {nav Edit>Preferences} and restart QuPath
{F18165963,width = 500}
When QuPath is restarted, a BIOP menu should appear on top of the QuPath window:
{F18022329,width = 500}
= WSI registration - step by step procedure
To follow the WSI registration procedure, a demo dataset, consisting of a fluorescent image which can be registered to a RGB H-DAB image, can be [downloaded here](https://zenodo.org/record/4680455#.YHQk3D-xW00).
== Create your QuPath project
[Create first a QuPath project](https://qupath.readthedocs.io/en/latest/docs/tutorials/projects.html) containing all the slides that you want to register.
{F18022361, width = 400}
WARNING: Only the Bio-Formats image builder is supported on the Fiji side. Make sure to select `Bio-Formats builder` when importing your slides, and leave unchecked `Auto generate pyramids`.
If your image can't be loaded in QuPath using the `Bio-Formats builder`, you can convert your slides in `ome.tiff` format. Several options are available, for instance by using [bfconvert with Kheops](https://c4science.ch/w/bioimaging_and_optics_platform_biop/image-processing/imagej_tools/ijp-kheops/), or [bioformatsf2raw](https://c4science.ch/w/bioimaging_and_optics_platform_biop/image-processing/qupath/ome-tiff-conversion/) for a fast conversion.
WARNING: All files need to be properly calibrated (microns, millimeters, etc, but not pixels!). Check on the image tab of QuPath that you have a proper physical unit specified, and not pixels!
{F18022412,width = 400}
Save your project, and you are done for now on the QuPath side.
NOTE: You can let QuPath open while performing the registration on Fiji.
== Registration in Fiji
=== Open your QuPath project
In Fiji, open your QuPath project using {nav Plugins › BigDataViewer › Playground › BDVDataset › Open [QuPath Project] }. You can also directly type `QuPath` in Fiji's search bar to avoid struggling in Fiji's menu hierarchy.
* Select your qupath project file (usually named `project.qpproj`).
* Let the default options but make sure to select **MILLIMETER** in the `physical units of the dataset` field
{F18022564,width = 400}
NOTE: the `physical units of the dataset` field actually indicates how you want to import your dataset. Bio-Formats takes care of converting the unit of the acquisition into millimeters. This can be achieved only if the image is correctly calibrated initially: bio-formats knows how to converts from microns to millimeters, or from angström to millimeters, but it can't know how to transform from pixels to millimeters.
NOTE: this WSI registration workflow hides many registration parameters by making use of the proper calibration in physical units, and by assuming it targets a cellular resolution level (do not expect registration precision at 50 nm resolution, unless you manually correct it with BigWarp).
After you have opened your Project, a window called `BDV Sources` should pop-up. If you double click on the `Sources` node, you should be able to browse the hierarchy and see the "sources" contained in your QuPath project. Note that the fluorescent channels have been splitted into separated sources. In the demo file, you get a window like this:
{F18022649,width =250}
* `DAB.tif-ch0` is the RGB DAB image
* `TileScan_001_Merging001-ch0` is the DAPI fluorescent channel
* `TileScan_001_Merging001-ch1` is the other fluorescent channel, which staining is similar to DAB
For the demo dataset registration, you can choose the DAB image as the fixed image, and the DAPI channel as the moving image.
=== Coarse manual pre-registration
The automated registration works if the images are approximately pre-aligned in the world coordinate space. This section explains how to check and correct the initial location of sources if they are not approximately aligned.
NOTE: If you do not want to use automated registrations, you can skip this part and just go to the next Wizard section and select `manual BigWarp registration` in the wizard.
To check if this is the case, you will need to display the two slides you want to align in a BigDataViewer window. To do this:
* select the slides that you want to align in the tree view. For this, you may find convenient to expand {nav SpimData 0> QuPathEntryEntity}, and select, using `ctrl+click`, the two entities you want to align:
{F18022728,width = 250}
* With these selected, right-click and select `BDV - Show Sources (new BDV Window)`
{F18022737,width = 400}
* Select the options as below:
{F18022742,width = 500}
* For the demo dataset, you will get something like this:
{F18022750,width = 600}
You can hover with your mouse on the right part of the panel to see a blue arrow that you can click:
{F18269212, width = 600}
With this right panel you can activate or deactivate sources. You notice that the fluorescent image, while of the correct size, is shifted in XY to the DAB image. This needs to be corrected before going further. If your images are already approximately aligned, you can skip the part below and go to the wizard section.
NOTE: Navigating within BigDataViewer requires a bit of experience. In 2D, the minimal commands to know are written below:
- **hold and drag right-click**: Pan;
- **mouse wheel (or up / down key)**: zoom in and out;
- **`shift` modifier key**: zoom in or out faster,
- **`ctrl` modifier key**: more precise zoom.
- You'll soon notice that holding **`left-click`** rotates the view. To go back to the default rotation, click **`shift+Z`**
You need to modify the location of the fluorescent image in order to approximately put it at its proper location. Here's a way to manually do it:
* Select the fluorescent sources in the tree view (all fluorescent channels should be selected, either by selecting an upstream node, like in the picture below, or by selected both fluorescent channels)
{F18024665, width=250}
* Right-click and select `Manual Sources Transformation`, choose mutate or append (it doesn't matter for this use case):
{F18024672, width=400}
{F18024676, width=250}
* Center the sources by panning the bdv window, the selected sources in the tree view will stay still (you stay in the referential of the moving sources)
{F18024689, size=full}
{F18024694, size=full}
* Click `Apply and finish` (or `Cancel` and then repeat the operation if something went wrong)
You now have an approximately registered slide to one another.
{F18024730, size=full}
Congrats, you can go to the next step.
=== Wizard : automated registration
You can start the wizard by clicking {nav Plugins › BigDataViewer › Playground › Sources › Register › Wizard Align Slides For QuPath} or just type `Wizard` in the search bar and select the correct command when it shows up.
First, select the DAB source as the fixed source, and the DAPI channel as the moving source that will be used for the registration as indicated in the image below:
{F18024767, width=700}
Another wizard window shows up:
{F18024780, width=700}
Successive steps of registration happens consecutively, all are optional. If the sample is not too streched or damaged from one scan to the other, a fully automated registration (skipping step 2 - Manual spline registration (BigWarp) ) will give cellular resoution results, but it's a good idea to check the results with BigWarp anyway, even if the landmarks are not modified because the registration is already tipptopp.
NOTE: If you check `show results of automated registrations`, ImageJ1 images will be created and show the different images which are effectively sent to elastix for automated registration. It's a good way to check the intermediate steps and see what could have gone wrong. However, the processing will be slower because each step happen sequentially instead of in a parallel fashion.
In the rest of this section, we assume all registration steps have been checked. If not, some of the details below will not be asked.
==== Step 1 - Set Bdv window to cover both moving and fixed slide
{F18024883, width=250}
During this step, you just need to have a bdv window open and selected and all the area of the slides you want to register should be visible, as in the image below:
{F18024899, width=700}
Click `OK` to go to the second step
==== Step 2 - Define a rectangular ROI for the registration
TOFIX: It's not clearly visible, but there's actually a message overlaid in BDV: `Select a rectangular region for the region you want to register`. TODO : Github Issue
{F18024912, width=700}
So just draw a rectangle spanning the region you want to register, by drawing a rectangle on bdv, holding mouse left button:
{F18024943, width=700}
==== Step 3 - Define position of landmarks that should be automatically registered
TOFIX : It's not clearly visible, but there's actually a message overlaid in BDV: `Select the position of the landmarks`
{F18024960, width=700}
Using the mouse left button, position points that will be used to locally correct the warping of the moving slide. You can concentrate the landmark on the regions you are more interested in. Here's an example of landmarks positionning:
{F18024977, width=700}
The number of necessary landmarks is not obvious to know in advance. You need to place them however where common structures are easily identifiable in both the moving and fixed image, a bit like how you would place focus points during your acquisition.
NOTE: To go to the next step, just press `Escape`. This part of the UI needs improvement (TODO : github issue)
NOTE: The automated registration should take about 20 seconds. If it takes longer, check that there's no error message in the ImageJ console.
==== Step 4 - Manually correct landmarks
If you have selected `Manual spline registration (BigWarp)`, you will now be able to manually investigate and correct landmarks that have been automatically registered, and also add new landmarks to the slides, if you want to adjust more precisely a particular region. The interface used is directly the one of [BigWarp](https://imagej.github.io/plugins/bigwarp), so please check the documentation of BigWarp itself in order to edit landmarks.
Here's a convenient way to perform this step:
* First, ignore the moving image window and increase the size of the BigWarp fixed image.
{F18025076, width=700}
* press `F1` for help window
* press `F` to toggle ON and OFF the registered moving image (F stands for fused)
* zoom (mouse wheel) and pan (drag left? or right? TOFIX mouse button) to investigate the registration quality
* press `ctrl+D` to move to the next landmark
To correct a landmark position:
* press `space` to enter the landmark mode
* carefully select and drag a landmark to modify its position. Live visualization of the transformed image helps you positioning it correctly
* press `space` to exit landmark mode
* navigate and repeat for each landmark that needs correction
To add another landmark:
* in landmark mode, press `ctrl + left click` to pin a new landmark on both the moving and fixed image at the current mouse location. It can then be dragged.
Once you are satisfied with the registration, click `OK`
{F18025114, width=300}
==== Step 5 - Succesful registration message
If all went smoothly, you should get this message:
{F18025129, width=300}
This means that the result of the registration has been stored as a file into your QuPath project. It can then be used from within QuPath to transfer annotations and or detections from one slide to another one, as explained in the next section.
NOTE: the transformation is stored as a json file in the data entry folder of the TOFIX fixed?moving? image. It is named by convention `transform_{i}_{j}.json` where `i` and `j` are the index of the fixed and the the moving image in the QuPath project.
== Analysis in QuPath
From within QuPath, annotations and or detections can be transfered within registered images, one way or another. Indeed, provided transformations are regular enough, they are invertible.
To transfer annotations or detections from one image to another:
* using the procedure of your choice (cell detection plugin, stardist, manual annotation, etc.), create annotations or detections on the image of your choice (for instance the moving image).
* move to the other registered image (for instance the fixed image).
* you can then execute the following script {nav Automate > User scripts... > New Script... }:
```
lang=javascript, name=transform_objects.groovy
import ch.epfl.biop.qupath.transform.TransformHelper
// Get the current image data
def imageData = getCurrentImageData()
// Transfer all matching annotations and detections, keeps hierarchy,
// transfer measurements (first true parameter)
// allow to use inverse transforms (second true parameter)
TransformHelper.transferMatchingAnnotationsToImage(imageData, true, true)
// Computes all intensities measurements in the new image
def server = getCurrentServer()
TransformHelper.addIntensityMeasurements(getAnnotationObjects(), server, 1, true)
//If the image is RGB, this line can be added to import the correct measurements (DAB, etc.) :
//
//server = new qupath.lib.images.servers.TransformedServerBuilder(getCurrentServer())
// .deconvolveStains(getCurrentImageData().getColorDeconvolutionStains(), 1, 2)
// .build()
//cf https://forum.image.sc/t/transferring-segmentation-predictions-from-custom-masks-to-qupath/43408/15
```
The above scripts consists of two parts:
* `TransformHelper.transferMatchingAnnotationsToImage` looks through all images of the QuPath project if there are transformations files will allow to transfer annotations and detections from one image to the current (target) one, and then performs the transfer.
* transfered annotations/detections does not contain the standard measurements provided by QuPath (fluorescent intensity / DAB value, etc.) In order to add the measurements on the target image, the function `TransformHelper.addIntensityMeasurements(getAnnotationObjects(), server, 1, true)` can be called
== Troubleshooting
Something's wrong in this documentation ? Please post your issue or question in the [image.sc forum](image.sc forum).
== References (papers)
* [Fiji](http://www.nature.com/nmeth/journal/v9/n7/full/nmeth.2019.html)
* [QuPath](https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5715110/)
* [BigWarp](http://ieeexplore.ieee.org/document/7493463/)
* [Elastix (1)](http://dx.doi.org/10.1109/TMI.2009.2035616) [Elastix (2)](http://dx.doi.org/10.3389/fninf.2013.00050)
* [BigDataViewer](http://www.nature.com/nmeth/journal/v12/n6/full/nmeth.3392.html)
== References (github)
The code to perform this workflow is splitted in several parts:
[Qupath extensions](https://github.com/BIOP/qupath-biop-extensions) and several repositories for the fiji side. On the fiji side, the main components are [Bigdataviewer-playground](https://github.com/bigdataviewer/bigdataviewer-playground) for the management of multiple sources and [Bigdataviewer-biop-tools](https://github.com/BIOP/bigdataviewer-biop-tools), for various functionalities, for instance the QuPath bridge.
c4science · Help