FORT
Communication
Protocol
Specification
##
Overview
The
Communication
protocol
is
built
upon
CAN
Bus
2.0
A
.
According
to
the
OSI
model
it
could
be
described
has
the
following
###
Physical
and
Data
Link
Layer
[
CAN
Bus
2.0
A
(
11
-
bit
identifier
)](
https
:
//en.wikipedia.org/wiki/CAN_bus#Base_frame_format)
specification
running
at
250
kbit
/
s
.
###
Network
Layer
The
network
consits
of
an
host
,
usually
a
desktop
computer
running
Linux
,
and
a
set
of
nodes
.
The
host
listen
and
acknowledge
any
message
on
the
CAN
bus
.
Each
node
has
an
unique
9
bit
identifier
.
Each
physical
node
is
configured
to
respond
to
a
certain
set
of
CAN
identifier
alone
on
the
bus
,
i
.
e
.
for
any
message
identifier
,
only
one
single
node
could
emit
and
should
listen
that
type
of
message
.
The
CAN
base
identifier
11
bit
are
subdicided
as
follow
to
specify
any
message
on
the
bus
:
<
table
>
<
tr
>
<
th
></
th
>
<
th
colspan
=
"2"
>
Message
Class
</
th
>
<
th
colspan
=
"6"
>
Message
Category
</
th
>
<
th
colspan
=
"3"
>
subID
</
th
>
</
tr
>
<
tr
>
<
th
>
Bit
</
th
>
<
td
>
10
</
td
>
<
td
>
9
</
td
>
<
td
>
8
</
td
>
<
td
>
7
</
td
>
<
td
>
6
</
td
>
<
td
>
5
</
td
>
<
td
>
4
</
td
>
<
td
>
3
</
td
>
<
td
>
2
</
td
>
<
td
>
1
</
td
>
<
td
>
0
</
td
>
</
tr
>
</
table
>
The
first
two
bits
are
used
to
specify
the
class
of
the
message
according
to
the
following
table
:
|
Bits
Value
|
Message
Class
|
Node
Permission
|
|------------------:|:----------------------------------------|:-----------------------|
|
0b00
|
Network
Control
Command
|
Receive
Only
|
|
0b01
|
High
Priority
Message
(
error
,
emergency
)|
Emission
and
Reception
|
|
0b10
|
Standard
Protoity
Messages
|
Emission
and
Reception
|
|
0b11
|
Heartbeat
message
|
Emission
Only
|
Except
for
control
messages
the
following
9
bit
are
subdivided
in
two
subset
,
a
6
bit
message
category
(
MSB
)
and
a
3
bit
subID
(
LSB
).
As
mentionned
before
only
one
single
node
over
the
bus
should
be
able
to
handle
an
unique
IDT
,
therefore
two
physically
identicate
board
should
be
used
on
the
bus
,
they
could
use
the
subID
field
to
specify
their
specific
message
.
The
special
subID
0b000
is
used
for
broadcasting
,
and
therefore
up
to
7
identical
device
can
work
on
the
bus
at
the
same
time
.
Any
node
on
the
bus
can
manage
several
message
category
,
as
it
will
be
describe
furtherly
.
The
unique
9
-
bit
identifier
of
a
node
consist
of
its
lowest
Message
Category
he
handles
and
its
subID
.
Network
control
Message
are
a
bit
more
perticular
.
They
are
always
broadcasted
the
message
category
is
used
to
specify
all
or
a
specifc
type
,
and
the
subID
is
used
to
convey
the
actual
command
.
###
Session
Layer
The
session
could
be
managed
using
heartbeat
message
.
The
host
can
use
a
Heartbeat
request
message
to
ask
for
all
or
for
a
specific
node
to
provide
a
heartbeat
every
X
milliseconds
.
This
heartbeat
could
be
used
to
monitor
which
node
are
available
.
The
same
command
could
be
used
to
specify
a
single
heartbeat
to
enumerate
all
present
node
on
the
bus
.
##
FORT
Standard
Message
Category
Table
and
Node
Class
ID
This
table
gives
all
message
categories
that
could
be
found
on
the
bus
.
|
Message
Category
|
Name
|
Node
|
Node
Class
ID
(
without
subID
)
|
|-----------------:|:----------------------------------------------|:-------------|:------------------------------|
|
0x00
|
Reserved
for
broadcast
|
none
and
all
|
n
.
a
.
|
|
0x01
|
Zeus
Temperature
and
Humidity
Periodic
Report
|
Zeus
|
0x01
|
|
0x02
|
Zeus
Temperature
and
Humidity
Set
Point
|
Zeus
|
0x01
|
|
0x03
-
0x08
|
Reserved
|
Zeus
|
0x01
|
|
0x09
|
Helios
Illumination
Set
Point
|
Helios
|
0x09
|
|
0x0a
-
0x0c
|
Reserved
|
Helios
|
0x09
|
|
0x0d
|
Celaeno
Humidity
Production
Set
Point
|
Celaeno
|
0x0d
|
|
0x0e
|
Celaeno
Water
Level
Status
|
Celaeno
|
0x0d
|
|
0x0f
-
0x10
|
Reserved
|
Celaeno
|
0x0d
|
|
0x11
-
0x3f
|
For
future
use
|
n
.
a
|
n
.
a
|
Any
of
this
messages
can
be
sent
using
low
(
0b10
)
and
high
(
0b01
)
priority
.
This
gives
the
following
class
ID
for
the
FORT
nodes
currently
available
:
|
Node
Name
|
Device
Class
ID
|
|----------:|:----------------|
|
Zeus
|
0x01
|
|
Helios
|
0x09
|
|
Celaeno
|
0x0d
|
For
all
messages
,
the
host
can
use
a
RTR
request
on
the
device
to
actively
fetch
the
data
if
he
requires
it
and
this
data
is
not
sent
periodically
.
##
Message
Specifications
.
####
0x01
Zeus
Temperature
and
Humidity
Report
*
Access
:
Read
Only
*
Periodically
emitted
by
node
:
yes
(
frequency
not
yet
determined
)
*
Write
:
n
.
a
.
*
Read
:
*
Data
Length
:
to
be
determined
.
*
Data
Fields
:
to
be
determined
.
####
0x02
Zeus
Temperature
and
Humidity
Set
Point
*
Access
:
Read
/
Write
*
Periodically
emitted
by
node
:
never
*
Read
/
Write
:
*
Data
Length
:
to
be
determined
.
*
Data
fields
:
to
be
determined
.
####
0x09
Helios
Illumination
Set
Point
*
Access
:
Read
/
Write
*
Periodically
emitted
by
node
:
never
*
Read
/
Write
:
*
Data
Length
:
2
*
Data
fields
:
*
Byte
0
:
Visible
Light
Amount
level
from
none
to
max
(
255
).
*
Byte
1
:
UV
Light
Level
Note
,
unstar
the
previous
system
,
the
infrared
light
pulse
duration
is
managed
by
the
framegrabber
.
####
0x0d
Celaeno
Humidity
Production
Set
Point
*
Access
:
Read
/
Write
*
Periodically
emitted
by
node
:
never
*
Read
/
Write
:
*
Data
Length
:
1
*
Data
fields
:
*
Byte
0
:
Amount
of
humidity
currently
produced
.
####
0x0e
Celaeno
Water
Level
*
Access
:
Read
*
Periodically
emitted
by
node
:
yes
on
exceptional
situation
(
warning
/
critical
level
reached
).
*
Write
:
n
.
a
.
*
Read
:
*
Data
Length
:
2
*
Data
fields
:
*
Byte
0
:
*
0xff
-
0x02
:
Functionning
Normally
*
0x01
:
Warning
Level
Reached
*
0x00
:
Critical
Level
Reached
,
Humidity
Production
Disabled
.
##
FORT
Network
Control
Command
Specification
As
mentionned
previously
,
Network
Control
Command
are
specified
differently
:
*
The
category
field
is
used
to
target
specific
node
class
,
or
0x00
to
broadcast
to
all
classes
*
The
subID
field
is
used
as
a
command
specification
,
all
node
of
the
same
class
are
broadcasted
.
The
following
command
are
specified
,
note
that
for
some
their
implementation
is
not
necesarly
required
|
Code
|
Command
|
Implementation
|
|-------|---------------------------|----------------|
|
0b000
|
Software
Reset
Request
|
Required
|
|
0b001
|
Timestamp
Synchrnoization
|
Optional
|
|
0b111
|
Heartbeat
Request
|
Required
|
As
these
message
are
broadcasted
,
the
RTR
beat
should
always
be
set
to
zero
.
###
0b000
Software
Reset
Request
Any
node
on
the
bus
should
implement
this
feature
and
reset
itself
after
acknowledgement
.
The
expected
data
length
is
0
byte
.
###
0b001
Timestamp
Synchronisation
Not
specified
yet
,
be
if
timestamped
data
would
be
required
on
the
bus
,
this
high
priority
frame
should
be
used
for
re
-
synchronizing
node
clocks
to
the
Host
one
.
###
0b111
Heartbeat
Request
This
command
is
used
to
request
for
the
targeted
nodes
to
transmit
an
heartbeat
.
The
Host
specifies
an
Heartbeat
period
in
ms
,
and
the
targeted
nodes
are
expected
to
transmit
an
heartbeat
periodically
after
acknowledgment
.
If
the
period
is
0
or
simply
omitted
,
a
single
heartbeat
request
should
be
sent
by
the
targeted
nodes
.
*
Data
Length
:
0
or
2
*
Data
Field
:
*
Byte
0
:
Heartbeat
period
LSB
*
Byte
1
:
Heartbeat
period
MSB
##
Heartbeat
Message
Specification
Heartbeat
message
are
issued
by
nodes
to
monitor
all
the
nodes
status
.
The
CAN
IDT
would
consist
of
0b11
followed
by
the
node
unique
ID
(
Node
Class
+
subID
).
In
the
case
the
heartbeat
is
emitted
following
a
single
heartbeat
request
(
node
enumeration
),
the
heartbeat
should
contain
a
firmware
version
information
.
In
case
of
heartbeat
periodically
sent
,
the
nodes
could
avoid
to
transmit
this
information
(
but
are
allowed
to
transmit
).
Firmware
version
consist
of
2
to
4
number
,
corresponding
to
Major
,
Minor
,
Patch
and
Tweak
numbering
*
Data
Length
0
,
2
,
3
or
4
.
*
Data
Field
:
*
Byte
0
:
Major
Version
number
(
required
if
any
versionning
is
transmitted
)
*
Byte
1
:
Minor
Version
number
(
required
if
any
versionning
is
transmitted
)
*
Byte
2
:
Patch
Version
number
(
optional
)
*
Byte
3
:
Tweak
Version
number
(
optional
)