Page Menu
Home
c4science
Search
Configure Global Search
Log In
Files
F91826566
replicate.h
No One
Temporary
Actions
Download File
Edit File
Delete File
View Transforms
Subscribe
Mute Notifications
Award Token
Subscribers
None
File Metadata
Details
File Info
Storage
Attached
Created
Thu, Nov 14, 21:16
Size
2 KB
Mime Type
text/x-c
Expires
Sat, Nov 16, 21:16 (2 d)
Engine
blob
Format
Raw Data
Handle
22330798
Attached To
rLAMMPS lammps
replicate.h
View Options
/* -*- c++ -*- ----------------------------------------------------------
LAMMPS - Large-scale Atomic/Molecular Massively Parallel Simulator
http://lammps.sandia.gov, Sandia National Laboratories
Steve Plimpton, sjplimp@sandia.gov
Copyright (2003) Sandia Corporation. Under the terms of Contract
DE-AC04-94AL85000 with Sandia Corporation, the U.S. Government retains
certain rights in this software. This software is distributed under
the GNU General Public License.
See the README file in the top-level LAMMPS directory.
------------------------------------------------------------------------- */
#ifdef COMMAND_CLASS
CommandStyle
(
replicate
,
Replicate
)
#else
#ifndef LMP_REPLICATE_H
#define LMP_REPLICATE_H
#include "pointers.h"
namespace
LAMMPS_NS
{
class
Replicate
:
protected
Pointers
{
public:
Replicate
(
class
LAMMPS
*
);
void
command
(
int
,
char
**
);
};
}
#endif
#endif
/* ERROR/WARNING messages:
E: Replicate command before simulation box is defined
The replicate command cannot be used before a read_data, read_restart,
or create_box command.
E: Illegal ... command
Self-explanatory. Check the input script syntax and compare to the
documentation for the command. You can use -echo screen as a
command-line option when running LAMMPS to see the offending line.
E: Cannot replicate 2d simulation in z dimension
The replicate command cannot replicate a 2d simulation in the z
dimension.
W: Replicating in a non-periodic dimension
The parameters for a replicate command will cause a non-periodic
dimension to be replicated; this may cause unwanted behavior.
E: Cannot replicate with fixes that store atom quantities
Either fixes are defined that create and store atom-based vectors or a
restart file was read which included atom-based vectors for fixes.
The replicate command cannot duplicate that information for new atoms.
You should use the replicate command before fixes are applied to the
system.
E: Replicated system atom IDs are too big
See the setting for tagint in the src/lmptype.h file.
E: Replicated system is too big
See the setting for bigint in the src/lmptype.h file.
E: Replicate did not assign all atoms correctly
Atoms replicated by the replicate command were not assigned correctly
to processors. This is likely due to some atom coordinates being
outside a non-periodic simulation box.
*/
Event Timeline
Log In to Comment