<li>ID, group-ID are documented in <a class="reference internal" href="fix.html"><span class="doc">fix</span></a> command</li>
<li>style_name = <em>nvt</em> or <em>npt</em> or <em>nph</em></li>
<li>one or more keyword/value pairs may be appended</li>
</ul>
<pre class="literal-block">
keyword = <em>temp</em> or <em>iso</em> or <em>aniso</em> or <em>tri</em> or <em>x</em> or <em>y</em> or <em>z</em> or <em>xy</em> or <em>yz</em> or <em>xz</em> or <em>couple</em> or <em>tchain</em> or <em>pchain</em> or <em>mtk</em> or <em>tloop</em> or <em>ploop</em> or <em>nreset</em> or <em>drag</em> or <em>dilate</em> or <em>scalexy</em> or <em>scaleyz</em> or <em>scalexz</em> or <em>flip</em> or <em>fixedpoint</em> or <em>update</em>
<em>temp</em> values = Tstart Tstop Tdamp
Tstart,Tstop = external temperature at start/end of run
Tdamp = temperature damping parameter (time units)
<em>iso</em> or <em>aniso</em> or <em>tri</em> values = Pstart Pstop Pdamp
Pstart,Pstop = scalar external pressure at start/end of run (pressure units)
Pdamp = pressure damping parameter (time units)
<em>x</em> or <em>y</em> or <em>z</em> or <em>xy</em> or <em>yz</em> or <em>xz</em> values = Pstart Pstop Pdamp
Pstart,Pstop = external stress tensor component at start/end of run (pressure units)
Pdamp = stress damping parameter (time units)
<em>couple</em> = <em>none</em> or <em>xyz</em> or <em>xy</em> or <em>yz</em> or <em>xz</em>
<em>tchain</em> value = N
N = length of thermostat chain (1 = single thermostat)
<em>pchain</em> values = N
N length of thermostat chain on barostat (0 = no thermostat)
<em>mtk</em> value = <em>yes</em> or <em>no</em> = add in MTK adjustment term or not
<em>tloop</em> value = M
M = number of sub-cycles to perform on thermostat
<em>ploop</em> value = M
M = number of sub-cycles to perform on barostat thermostat
<em>nreset</em> value = reset reference cell every this many timesteps
<em>drag</em> value = Df
Df = drag factor added to barostat/thermostat (0.0 = no drag)
<em>dilate</em> value = dilate-group-ID
dilate-group-ID = only dilate atoms in this group due to barostat volume changes
<em>scalexy</em> value = <em>yes</em> or <em>no</em> = scale xy with ly
<em>scaleyz</em> value = <em>yes</em> or <em>no</em> = scale yz with lz
<em>scalexz</em> value = <em>yes</em> or <em>no</em> = scale xz with lz
<em>flip</em> value = <em>yes</em> or <em>no</em> = allow or disallow box flips when it becomes highly skewed
<em>fixedpoint</em> values = x y z
x,y,z = perform barostat dilation/contraction around this point (distance units)
<em>update</em> value = <em>dipole</em> update dipole orientation (only for sphere variants)
<p>These commands perform time integration on Nose-Hoover style
non-Hamiltonian equations of motion which are designed to generate
positions and velocities sampled from the canonical (nvt),
isothermal-isobaric (npt), and isenthalpic (nph) ensembles. This
updates the position and velocity for atoms in the group each
timestep.</p>
<p>The thermostatting and barostatting is achieved by adding some dynamic
variables which are coupled to the particle velocities
(thermostatting) and simulation domain dimensions (barostatting). In
addition to basic thermostatting and barostatting, these fixes can
also create a chain of thermostats coupled to the particle thermostat,
and another chain of thermostats coupled to the barostat
variables. The barostat can be coupled to the overall box volume, or
to individual dimensions, including the <em>xy</em>, <em>xz</em> and <em>yz</em> tilt
dimensions. The external pressure of the barostat can be specified as
either a scalar pressure (isobaric ensemble) or as components of a
symmetric stress tensor (constant stress ensemble). When used
correctly, the time-averaged temperature and stress tensor of the
particles will match the target values specified by Tstart/Tstop and
Pstart/Pstop.</p>
<p>The equations of motion used are those of Shinoda et al in
<a class="reference internal" href="pair_sdk.html#shinoda"><span class="std std-ref">(Shinoda)</span></a>, which combine the hydrostatic equations of
Martyna, Tobias and Klein in <a class="reference internal" href="#martyna"><span class="std std-ref">(Martyna)</span></a> with the strain
energy proposed by Parrinello and Rahman in
<a class="reference internal" href="#parrinello"><span class="std std-ref">(Parrinello)</span></a>. The time integration schemes closely
follow the time-reversible measure-preserving Verlet and rRESPA
integrators derived by Tuckerman et al in <a class="reference internal" href="fix_pimd.html#tuckerman"><span class="std std-ref">(Tuckerman)</span></a>.</p>
<hr class="docutils" />
<p>The thermostat parameters for fix styles <em>nvt</em> and <em>npt</em> is specified
using the <em>temp</em> keyword. Other thermostat-related keywords are
<em>tchain</em>, <em>tloop</em> and <em>drag</em>, which are discussed below.</p>
<p>The thermostat is applied to only the translational degrees of freedom
for the particles. The translational degrees of freedom can also have
a bias velocity removed before thermostatting takes place; see the
description below. The desired temperature at each timestep is a
ramped value during the run from <em>Tstart</em> to <em>Tstop</em>. The <em>Tdamp</em>
parameter is specified in time units and determines how rapidly the
temperature is relaxed. For example, a value of 10.0 means to relax
the temperature in a timespan of (roughly) 10 time units (e.g. tau or
fmsec or psec - see the <a class="reference internal" href="units.html"><span class="doc">units</span></a> command). The atoms in the
fix group are the only ones whose velocities and positions are updated
by the velocity/position update portion of the integration.</p>
<div class="admonition note">
<p class="first admonition-title">Note</p>
<p class="last">A Nose-Hoover thermostat will not work well for arbitrary values
of <em>Tdamp</em>. If <em>Tdamp</em> is too small, the temperature can fluctuate
wildly; if it is too large, the temperature will take a very long time
to equilibrate. A good choice for many models is a <em>Tdamp</em> of around
100 timesteps. Note that this is NOT the same as 100 time units for
most <a class="reference internal" href="units.html"><span class="doc">units</span></a> settings.</p>
</div>
<hr class="docutils" />
<p>The barostat parameters for fix styles <em>npt</em> and <em>nph</em> is specified
using one or more of the <em>iso</em>, <em>aniso</em>, <em>tri</em>, <em>x</em>, <em>y</em>, <em>z</em>, <em>xy</em>,
<em>xz</em>, <em>yz</em>, and <em>couple</em> keywords. These keywords give you the
ability to specify all 6 components of an external stress tensor, and
to couple various of these components together so that the dimensions
they represent are varied together during a constant-pressure
simulation.</p>
<p>Other barostat-related keywords are <em>pchain</em>, <em>mtk</em>, <em>ploop</em>,
<em>nreset</em>, <em>drag</em>, and <em>dilate</em>, which are discussed below.</p>
<p>Orthogonal simulation boxes have 3 adjustable dimensions (x,y,z).
Triclinic (non-orthogonal) simulation boxes have 6 adjustable
specify whether the simulation box is orthogonal or non-orthogonal
(triclinic) and explain the meaning of the xy,xz,yz tilt factors.</p>
<p>The target pressures for each of the 6 components of the stress tensor
can be specified independently via the <em>x</em>, <em>y</em>, <em>z</em>, <em>xy</em>, <em>xz</em>, <em>yz</em>
keywords, which correspond to the 6 simulation box dimensions. For
each component, the external pressure or tensor component at each
timestep is a ramped value during the run from <em>Pstart</em> to <em>Pstop</em>.
If a target pressure is specified for a component, then the
corresponding box dimension will change during a simulation. For
example, if the <em>y</em> keyword is used, the y-box length will change. If
the <em>xy</em> keyword is used, the xy tilt factor will change. A box
dimension will not change if that component is not specified, although
you have the option to change that dimension via the <a class="reference internal" href="fix_deform.html"><span class="doc">fix deform</span></a> command.</p>
<p>Note that in order to use the <em>xy</em>, <em>xz</em>, or <em>yz</em> keywords, the
simulation box must be triclinic, even if its initial tilt factors are
0.0.</p>
<p>For all barostat keywords, the <em>Pdamp</em> parameter operates like the
<em>Tdamp</em> parameter, determining the time scale on which pressure is
relaxed. For example, a value of 10.0 means to relax the pressure in
a timespan of (roughly) 10 time units (e.g. tau or fmsec or psec - see
the <a class="reference internal" href="units.html"><span class="doc">units</span></a> command).</p>
<div class="admonition note">
<p class="first admonition-title">Note</p>
<p class="last">A Nose-Hoover barostat will not work well for arbitrary values
of <em>Pdamp</em>. If <em>Pdamp</em> is too small, the pressure and volume can
fluctuate wildly; if it is too large, the pressure will take a very
long time to equilibrate. A good choice for many models is a <em>Pdamp</em>
of around 1000 timesteps. However, note that <em>Pdamp</em> is specified in
time units, and that timesteps are NOT the same as time units for most
does the same thing for the barostat thermostat.</p>
<p>The keyword <em>nreset</em> controls how often the reference dimensions used
to define the strain energy are reset. If this keyword is not used,
or is given a value of zero, then the reference dimensions are set to
those of the initial simulation domain and are never changed. If the
simulation domain changes significantly during the simulation, then
the final average pressure tensor will differ significantly from the
specified values of the external stress tensor. A value of <em>nstep</em>
means that every <em>nstep</em> timesteps, the reference dimensions are set
to those of the current simulation domain.</p>
<p>The <em>scaleyz</em>, <em>scalexz</em>, and <em>scalexy</em> keywords control whether or
not the corresponding tilt factors are scaled with the associated box
dimensions when barostatting triclinic periodic cells. The default
values <em>yes</em> will turn on scaling, which corresponds to adjusting the
linear dimensions of the cell while preserving its shape. Choosing
<em>no</em> ensures that the tilt factors are not scaled with the box
dimensions. See below for restrictions and default values in different
situations. In older versions of LAMMPS, scaling of tilt factors was
not performed. The old behavior can be recovered by setting all three
scale keywords to <em>no</em>.</p>
<p>The <em>flip</em> keyword allows the tilt factors for a triclinic box to
exceed half the distance of the parallel box length, as discussed
below. If the <em>flip</em> value is set to <em>yes</em>, the bound is enforced by
flipping the box when it is exceeded. If the <em>flip</em> value is set to
<em>no</em>, the tilt will continue to change without flipping. Note that if
applied stress induces large deformations (e.g. in a liquid), this
means the box shape can tilt dramatically and LAMMPS will run less
efficiently, due to the large volume of communication needed to
acquire ghost atoms around a processor’s irregular-shaped sub-domain.
For extreme values of tilt, LAMMPS may also lose atoms and generate an
error.</p>
<p>The <em>fixedpoint</em> keyword specifies the fixed point for barostat volume
changes. By default, it is the center of the box. Whatever point is
chosen will not move during the simulation. For example, if the lower
periodic boundaries pass through (0,0,0), and this point is provided
to <em>fixedpoint</em>, then the lower periodic boundaries will remain at
(0,0,0), while the upper periodic boundaries will move twice as
far. In all cases, the particle trajectories are unaffected by the
chosen value, except for a time-dependent constant translation of
positions.</p>
<p>If the <em>update</em> keyword is used with the <em>dipole</em> value, then the
orientation of the dipole moment of each particle is also updated
during the time integration. This option should be used for models
where a dipole moment is assigned to finite-size particles,
e.g. spheroids via use of the <a class="reference internal" href="atom_style.html"><span class="doc">atom_style hybrid sphere dipole</span></a> command.</p>
<hr class="docutils" />
<div class="admonition note">
<p class="first admonition-title">Note</p>
<p class="last">Using a barostat coupled to tilt dimensions <em>xy</em>, <em>xz</em>, <em>yz</em> can
sometimes result in arbitrarily large values of the tilt dimensions,
i.e. a dramatically deformed simulation box. LAMMPS allows the tilt
factors to grow a small amount beyond the normal limit of half the box
length (0.6 times the box length), and then performs a box “flip” to
an equivalent periodic cell. See the discussion of the <em>flip</em> keyword
above, to allow this bound to be exceeded, if desired.</p>
</div>
<p>The flip operation is described in more detail in the doc page for
<a class="reference internal" href="fix_deform.html"><span class="doc">fix deform</span></a>. Both the barostat dynamics and the atom
trajectories are unaffected by this operation. However, if a tilt
factor is incremented by a large amount (1.5 times the box length) on
a single timestep, LAMMPS can not accomodate this event and will
terminate the simulation with an error. This error typically indicates
that there is something badly wrong with how the simulation was
constructed, such as specifying values of <em>Pstart</em> that are too far
from the current stress value, or specifying a timestep that is too
large. Triclinic barostatting should be used with care. This also is
true for other barostat styles, although they tend to be more
forgiving of insults. In particular, it is important to recognize that
equilibrium liquids can not support a shear stress and that
equilibrium solids can not support shear stresses that exceed the
yield stress.</p>
<p>One exception to this rule is if the 1st dimension in the tilt factor
(x for xy) is non-periodic. In that case, the limits on the tilt
factor are not enforced, since flipping the box in that dimension does
not change the atom positions due to non-periodicity. In this mode,
if you tilt the system to extreme angles, the simulation will simply
become inefficient due to the highly skewed simulation box.</p>
<div class="admonition note">
<p class="first admonition-title">Note</p>
<p class="last">Unlike the <a class="reference internal" href="fix_temp_berendsen.html"><span class="doc">fix temp/berendsen</span></a> command
which performs thermostatting but NO time integration, these fixes
perform thermostatting/barostatting AND time integration. Thus you
should not use any other time integration fix, such as <a class="reference internal" href="fix_nve.html"><span class="doc">fix nve</span></a> on atoms to which this fix is applied. Likewise,
fix nvt and fix npt should not normally be used on atoms that also
have their temperature controlled by another fix - e.g. by <a class="reference internal" href="#"><span class="doc">fix langevin</span></a> or <a class="reference internal" href="fix_temp_rescale.html"><span class="doc">fix temp/rescale</span></a>
commands.</p>
</div>
<p>See <a class="reference internal" href="Section_howto.html#howto-16"><span class="std std-ref">this howto section</span></a> of the manual for
a discussion of different ways to compute temperature and perform
thermostatting and barostatting.</p>
<hr class="docutils" />
<p>These fixes compute a temperature and pressure each timestep. To do
this, the fix creates its own computes of style “temp” and “pressure”,
as if one of these two sets of commands had been issued:</p>
<p>See the <a class="reference internal" href="compute_temp.html"><span class="doc">compute temp</span></a> and <a class="reference internal" href="compute_pressure.html"><span class="doc">compute pressure</span></a> commands for details. Note that the
IDs of the new computes are the fix-ID + underscore + “temp” or fix_ID
+ underscore + “press”. For fix nvt, the group for the new computes
is the same as the fix group. For fix nph and fix npt, the group for
the new computes is “all” since pressure is computed for the entire
system.</p>
<p>Note that these are NOT the computes used by thermodynamic output (see
the <a class="reference internal" href="thermo_style.html"><span class="doc">thermo_style</span></a> command) with ID = <em>thermo_temp</em>
and <em>thermo_press</em>. This means you can change the attributes of this
fix’s temperature or pressure via the
<a class="reference internal" href="compute_modify.html"><span class="doc">compute_modify</span></a> command or print this temperature
or pressure during thermodynamic output via the <a class="reference internal" href="thermo_style.html"><span class="doc">thermo_style custom</span></a> command using the appropriate compute-ID.
It also means that changing attributes of <em>thermo_temp</em> or
<em>thermo_press</em> will have no effect on this fix.</p>
<p>Like other fixes that perform thermostatting, fix nvt and fix npt can
be used with <a class="reference internal" href="compute.html"><span class="doc">compute commands</span></a> that calculate a
temperature after removing a “bias” from the atom velocities.
E.g. removing the center-of-mass velocity from a group of atoms or
only calculating temperature on the x-component of velocity or only
calculating temperature for atoms in a geometric region. This is not
done by default, but only if the <a class="reference internal" href="fix_modify.html"><span class="doc">fix_modify</span></a> command
is used to assign a temperature compute to this fix that includes such
a bias term. See the doc pages for individual <a class="reference internal" href="compute.html"><span class="doc">compute commands</span></a> to determine which ones include a bias. In
this case, the thermostat works in the following manner: the current
temperature is calculated taking the bias into account, bias is
removed from each atom, thermostatting is performed on the remaining
thermal degrees of freedom, and the bias is added back in.</p>
<hr class="docutils" />
<p>These fixes can be used with either the <em>verlet</em> or <em>respa</em>
<a class="reference internal" href="run_style.html"><span class="doc">integrators</span></a>. When using one of the barostat fixes
with <em>respa</em>, LAMMPS uses an integrator constructed
according to the following factorization of the Liouville propagator
<p>The fix npt and fix nph commands can be used with rigid bodies or
mixtures of rigid bodies and non-rigid particles (e.g. solvent). But
there are also <a class="reference internal" href="fix_rigid.html"><span class="doc">fix rigid/npt</span></a> and <a class="reference internal" href="fix_rigid.html"><span class="doc">fix rigid/nph</span></a> commands, which are typically a more natural
choice. See the doc page for those commands for more discussion of
the various ways to do this.</p>
<hr class="docutils" />
<p>Styles with a <em>cuda</em>, <em>gpu</em>, <em>intel</em>, <em>kk</em>, <em>omp</em>, or <em>opt</em> suffix are
functionally the same as the corresponding style without the suffix.
They have been optimized to run faster, depending on your available
hardware, as discussed in <a class="reference internal" href="Section_accelerate.html"><span class="doc">Section_accelerate</span></a>
of the manual. The accelerated styles take the same arguments and
should produce the same results, except for round-off and precision
issues.</p>
<p>These accelerated styles are part of the USER-CUDA, GPU, USER-INTEL,
KOKKOS, USER-OMP and OPT packages, respectively. They are only
enabled if LAMMPS was built with those packages. See the <a class="reference internal" href="Section_start.html#start-3"><span class="std std-ref">Making LAMMPS</span></a> section for more info.</p>
<p>You can specify the accelerated styles explicitly in your input script
by including their suffix, or you can use the <a class="reference internal" href="Section_start.html#start-7"><span class="std std-ref">-suffix command-line switch</span></a> when you invoke LAMMPS, or you can
use the <a class="reference internal" href="suffix.html"><span class="doc">suffix</span></a> command in your input script.</p>
<p>See <a class="reference internal" href="Section_accelerate.html"><span class="doc">Section_accelerate</span></a> of the manual for
more instructions on how to use the accelerated styles effectively.</p>
<h2>Restart, fix_modify, output, run start/stop, minimize info</h2>
<p>These fixes writes the state of all the thermostat and barostat
variables to <a class="reference internal" href="restart.html"><span class="doc">binary restart files</span></a>. See the
<a class="reference internal" href="read_restart.html"><span class="doc">read_restart</span></a> command for info on how to re-specify
a fix in an input script that reads a restart file, so that the
operation of the fix continues in an uninterrupted fashion.</p>
<p>The <a class="reference internal" href="fix_modify.html"><span class="doc">fix_modify</span></a> <em>temp</em> and <em>press</em> options are
supported by these fixes. You can use them to assign a
<a class="reference internal" href="compute.html"><span class="doc">compute</span></a> you have defined to this fix which will be used
in its thermostatting or barostatting procedure, as described above.
If you do this, note that the kinetic energy derived from the compute
temperature should be consistent with the virial term computed using
all atoms for the pressure. LAMMPS will warn you if you choose to
compute temperature on a subset of atoms.</p>
<div class="admonition note">
<p class="first admonition-title">Note</p>
<p class="last">If both the <em>temp</em> and <em>press</em> keywords are used in a single
thermo_modify command (or in two separate commands), then the order in
which the keywords are specified is important. Note that a <a class="reference internal" href="compute_pressure.html"><span class="doc">pressure compute</span></a> defines its own temperature compute as
an argument when it is specified. The <em>temp</em> keyword will override
this (for the pressure compute being used by fix npt), but only if the
<em>temp</em> keyword comes after the <em>press</em> keyword. If the <em>temp</em> keyword
comes before the <em>press</em> keyword, then the new pressure compute
specified by the <em>press</em> keyword will be unaffected by the <em>temp</em>
setting.</p>
</div>
<p>The <a class="reference internal" href="fix_modify.html"><span class="doc">fix_modify</span></a> <em>energy</em> option is supported by these
fixes to add the energy change induced by Nose/Hoover thermostatting
and barostatting to the system’s potential energy as part of
<p>These fixes compute a global scalar and a global vector of quantities,
which can be accessed by various <a class="reference internal" href="Section_howto.html#howto-15"><span class="std std-ref">output commands</span></a>. The scalar value calculated by
these fixes is “extensive”; the vector values are “intensive”.</p>
<p>The scalar is the cumulative energy change due to the fix.</p>
<p>The vector stores internal Nose/Hoover thermostat and barostat
variables. The number and meaning of the vector values depends on
which fix is used and the settings for keywords <em>tchain</em> and <em>pchain</em>,
which specify the number of Nose/Hoover chains for the thermostat and
barostat. If no thermostatting is done, then <em>tchain</em> is 0. If no
barostatting is done, then <em>pchain</em> is 0. In the following list,
“ndof” is 0, 1, 3, or 6, and is the number of degrees of freedom in
the barostat. Its value is 0 if no barostat is used, else its value
is 6 if any off-diagonal stress tensor component is barostatted, else
its value is 1 if <em>couple xyz</em> is used or <em>couple xy</em> for a 2d
simulation, otherwise its value is 3.</p>
<p>The order of values in the global vector and their meaning is as
follows. The notation means there are tchain values for eta, followed
by tchain for eta_dot, followed by ndof for omega, etc:</p>
<li>PE_eta[tchain] = potential energy of each particle thermostat displacement (energy units)</li>
<li>KE_eta_dot[tchain] = kinetic energy of each particle thermostat velocity (energy units)</li>
<li>PE_omega[ndof] = potential energy of each barostat displacement (energy units)</li>
<li>KE_omega_dot[ndof] = kinetic energy of each barostat velocity (energy units)</li>
<li>PE_etap[pchain] = potential energy of each barostat thermostat displacement (energy units)</li>
<li>KE_etap_dot[pchain] = kinetic energy of each barostat thermostat velocity (energy units)</li>
<li>PE_strain[1] = scalar strain energy (energy units)</li>
</ul>
<p>These fixes can ramp their external temperature and pressure over
multiple runs, using the <em>start</em> and <em>stop</em> keywords of the
<a class="reference internal" href="run.html"><span class="doc">run</span></a> command. See the <a class="reference internal" href="run.html"><span class="doc">run</span></a> command for details of
how to do this.</p>
<p>These fixes are not invoked during <a class="reference internal" href="minimize.html"><span class="doc">energy minimization</span></a>.</p>
</div>
<hr class="docutils" />
<div class="section" id="restrictions">
<h2>Restrictions</h2>
<p><em>X</em>, <em>y</em>, <em>z</em> cannot be barostatted if the associated dimension is not
periodic. <em>Xy</em>, <em>xz</em>, and <em>yz</em> can only be barostatted if the
simulation domain is triclinic and the 2nd dimension in the keyword
(<em>y</em> dimension in <em>xy</em>) is periodic. <em>Z</em>, <em>xz</em>, and <em>yz</em>, cannot be
barostatted for 2D simulations. The <a class="reference internal" href="create_box.html"><span class="doc">create_box</span></a>,