Page Menu
Home
c4science
Search
Configure Global Search
Log In
Files
F92821783
angle_hybrid.html
No One
Temporary
Actions
Download File
Edit File
Delete File
View Transforms
Subscribe
Mute Notifications
Award Token
Subscribers
None
File Metadata
Details
File Info
Storage
Attached
Created
Sat, Nov 23, 23:30
Size
3 KB
Mime Type
text/html
Expires
Mon, Nov 25, 23:30 (1 d, 21 h)
Engine
blob
Format
Raw Data
Handle
22407700
Attached To
rLAMMPS lammps
angle_hybrid.html
View Options
<HTML>
<CENTER><A
HREF =
"http://lammps.sandia.gov"
>
LAMMPS WWW Site
</A>
-
<A
HREF =
"Manual.html"
>
LAMMPS Documentation
</A>
-
<A
HREF =
"Section_commands.html#comm"
>
LAMMPS Commands
</A>
</CENTER>
<HR>
<H3>
angle_style hybrid command
</H3>
<P><B>
Syntax:
</B>
</P>
<PRE>
angle_style hybrid style1 style2 ...
</PRE>
<UL><LI>
style1,style2 = list of one or more angle styles
</UL>
<P><B>
Examples:
</B>
</P>
<PRE>
angle_style hybrid harmonic cosine
angle_coeff 1 harmonic 80.0 30.0
angle_coeff 2* cosine 50.0
</PRE>
<P><B>
Description:
</B>
</P>
<P>
The
<I>
hybrid
</I>
style enables the use of multiple angle styles in one
simulation. An angle style is assigned to each angle type. For
example, angles in a polymer flow (of angle type 1) could be computed
with a
<I>
harmonic
</I>
potential and angles in the wall boundary (of angle
type 2) could be computed with a
<I>
cosine
</I>
potential. The assignment
of angle type to style is made via the
<A
HREF =
"angle_coeff.html"
>
angle_coeff
</A>
command or in the data file.
</P>
<P>
In the angle_coeff commands, the name of an angle style must be added
after the angle type, with the remaining coefficients being those
appropriate to that style. In the example above, the 2 angle_coeff
commands set angles of angle type 1 to be computed with a
<I>
harmonic
</I>
potential with coefficients 80.0, 30.0 for K, theta0. All other angle
types (2-N) are computed with a
<I>
cosine
</I>
potential with coefficient
50.0 for K.
</P>
<P>
If angle coefficients are specified in the data file read via the
<A
HREF =
"read_data.html"
>
read_data
</A>
command, then the same rule applies.
E.g. "harmonic" or "cosine", must be added after the angle type, for each
line in the "Angle Coeffs" section, e.g.
</P>
<PRE>
Angle Coeffs
</PRE>
<PRE>
1 harmonic 80.0 30.0
2 cosine 50.0
...
</PRE>
<P>
If
<I>
class2
</I>
is one of the angle hybrid styles, the same rule holds for
specifying additional BondBond (and BondAngle) coefficients either via
the input script or in the data file. I.e.
<I>
class2
</I>
must be added to
each line after the angle type. For lines in the BondBond (or
BondAngle) section of the data file for angle types that are not
<I>
class2
</I>
, you must use an angle style of
<I>
skip
</I>
as a placeholder, e.g.
</P>
<PRE>
BondBond Coeffs
</PRE>
<PRE>
1 skip
2 class2 3.6512 1.0119 1.0119
...
</PRE>
<P>
Note that it is not necessary to use the angle style
<I>
skip
</I>
in the
input script, since BondBond (or BondAngle) coefficients need not be
specified at all for angle types that are not
<I>
class2
</I>
.
</P>
<P>
An angle style of
<I>
none
</I>
with no additional coefficients can be used
in place of an angle style, either in a input script angle_coeff
command or in the data file, if you desire to turn off interactions
for specific angle types.
</P>
<HR>
<P><B>
Restrictions:
</B>
</P>
<P>
This angle style can only be used if LAMMPS was built with the
MOLECULE package (which it is by default). See the
<A
HREF =
"Section_start.html#start_3"
>
Making
LAMMPS
</A>
section for more info on packages.
</P>
<P>
Unlike other angle styles, the hybrid angle style does not store angle
coefficient info for individual sub-styles in a
<A
HREF =
"restart.html"
>
binary restart
files
</A>
. Thus when retarting a simulation from a restart
file, you need to re-specify angle_coeff commands.
</P>
<P><B>
Related commands:
</B>
</P>
<P><A
HREF =
"angle_coeff.html"
>
angle_coeff
</A>
</P>
<P><B>
Default:
</B>
none
</P>
</HTML>
Event Timeline
Log In to Comment