<li><on|off> = switch to activiate/deactiviate the intial setting of FE intrinsic field to match the projected MD field </li>
</ul>
<h2><a class="anchor" id="examples">
examples</a></h2>
<p><code> fix_modify atc consistent_fe_initialization on </code> </p>
<h2><a class="anchor" id="description">
description</a></h2>
<p>Determines whether AtC initializes FE intrinsic fields (e.g., temperature) to match the projected MD values. This is particularly useful for fully overlapping simulations. </p>
<h2><a class="anchor" id="restrictions">
restrictions</a></h2>
<p>Can be used with: thermal, two_temperature. Cannot be used with time filtering on. Does not include boundary nodes. </p>
<h2><a class="anchor" id="related">
related</a></h2>
<h2><a class="anchor" id="default">
default</a></h2>
<p>Default is off </p>
</div>